His Bundle Pacing in Atrial Fibrillation and HFpEF
Atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) frequently coexist, creating a clinical problem that is more complex than an apparently normal left ventricular ejection fraction might suggest. Patients may have exertional breathlessness, exercise intolerance, recurrent admissions and rapid ventricular rates, while conventional measures of systolic function remain within the preserved range.
His bundle pacing (HBP) is a form of conduction system pacing designed to activate the ventricles through the native His–Purkinje network. By placing a lead near the His bundle, clinicians aim to preserve physiological ventricular depolarisation and avoid some of the electrical dyssynchrony associated with right ventricular apical pacing.
The potential role of HBP is especially relevant when AF requires strict rate control, when atrioventricular (AV) node ablation is being considered, or when a patient has a high anticipated pacing burden. In HFpEF, however, the clinical rationale is often stronger than the available outcome evidence. Careful patient selection, procedural expertise and realistic expectations remain essential.
For Australian clinicians, decisions may also be shaped by access to electrophysiology services, local device expertise and the practical differences between metropolitan and regional care. A patient referred from regional New South Wales to Sydney, or from northern Queensland to Brisbane, may need a clear plan for implantation, programming, wound review and long-term device surveillance.
The clinical connection between AF and HFpEF
AF and HFpEF share several pathophysiological features, including age-related myocardial stiffness, hypertension, obesity, diabetes, sleep-disordered breathing and renal disease. Loss of atrial contraction can reduce ventricular filling, while an irregular and frequently rapid ventricular response can further impair diastolic filling and increase left atrial pressure.
A preserved ejection fraction does not mean that ventricular performance is normal in every respect. Chronotropic incompetence, impaired relaxation, abnormal ventricular–arterial coupling and elevated filling pressures may all contribute to symptoms. In a patient with AF, these abnormalities can be difficult to separate from the effects of tachycardia, medication intolerance or pulmonary disease.
Rate control is therefore frequently central to management. Beta blockers, digoxin and selected calcium-channel blockers may be useful in appropriate patients, although hypotension, chronotropic limitation and renal impairment can restrict treatment. Rhythm control, including catheter ablation, may improve symptoms for selected individuals, but persistent AF, marked atrial enlargement or advanced comorbidity can make durable sinus rhythm difficult to achieve.
When medication does not provide adequate rate control, or produces unacceptable adverse effects, AV node ablation with permanent pacing can offer reliable control of the ventricular rate. The pacing strategy then becomes clinically important, particularly in someone expected to be paced continuously for many years.
How His bundle pacing may preserve ventricular function
Conventional right ventricular pacing can create an activation pattern that differs from normal conduction. In patients with a substantial pacing burden, this may contribute to pacing-induced cardiomyopathy, worsening mitral regurgitation or heart failure symptoms. The risk is not identical for every patient, and HFpEF-specific data remain limited, but avoiding unnecessary electrical dyssynchrony is a reasonable objective.
HBP seeks to recruit the native conduction system. When capture is successful and stable, QRS duration may remain relatively narrow, potentially supporting more coordinated ventricular contraction. This is particularly attractive after AV node ablation, when the device assumes responsibility for every ventricular beat.
The approach may also be considered when a patient with AF has a reduced or borderline ejection fraction, an anticipated high pacing percentage, pre-existing bundle branch disease or a history suggesting vulnerability to conventional pacing. In HFpEF, the hoped-for benefit is often preservation of ventricular interaction and prevention of a decline in systolic function rather than an expected dramatic improvement in ejection fraction.
HBP is not equivalent to restoring atrial transport. It cannot correct the loss of atrial contraction caused by AF, and it does not directly treat elevated filling pressures, pulmonary hypertension or the systemic drivers of HFpEF. Its value lies in the ventricular activation strategy within a broader management plan.
Selecting patients and planning the procedure
A useful assessment begins with the reason pacing is being proposed. AV node ablation for uncontrolled AF is a different clinical scenario from bradycardia caused by medication, intermittent AV block or a need for pacing after another electrophysiology procedure. The anticipated pacing percentage, ventricular function, QRS morphology, comorbidities and likelihood of future rhythm-control treatment should all inform the decision.
Baseline echocardiography is important, including assessment of left ventricular ejection fraction, chamber size, right ventricular function, valvular disease and indicators of raised filling pressure. A 12-lead ECG can help identify conduction disease and establish a reference for later assessment of QRS morphology. Symptoms should be documented carefully because changes in exercise capacity after implantation may reflect rate regularity, medication adjustment or improved haemodynamics rather than pacing alone.
HBP can be technically demanding. His bundle anatomy varies, thresholds may be higher than with conventional ventricular pacing, and lead stability requires meticulous implantation and follow-up. In patients with distal conduction disease or difficult His capture, left bundle branch area pacing may be considered as an alternative form of conduction system pacing. The choice depends on operator experience, anatomy, equipment and the patient’s long-term needs.
Australian practice also involves practical considerations around device availability and follow-up. A patient treated in a private electrophysiology unit in Melbourne may have a different pathway from one managed through a public hospital in Perth or a regional centre in Tasmania. Clear communication with the referring cardiologist and local cardiac rhythm service is important before implantation, especially when remote monitoring and in-person threshold checks are arranged across long distances.
Evidence, limitations and follow-up
The strongest rationale for HBP currently comes from studies of conduction system pacing, pacing-dependent patients and selected cohorts undergoing AV node ablation. These studies generally support physiological activation and suggest favourable electrical outcomes, but they do not establish a universal mortality or hospitalisation benefit for people with AF and HFpEF.
Evidence in HFpEF is particularly incomplete. Many studies combine patients with different ejection fractions, pacing indications and rhythm histories. Small sample sizes, observational designs and variable definitions of clinical success make direct comparison difficult. Improvements in symptoms or echocardiographic measurements should therefore be interpreted alongside hospital admissions, functional status, quality of life and adverse events.
Follow-up should include interrogation of capture thresholds, sensing, impedance, battery trajectory and the percentage of ventricular pacing. The ECG can help assess whether His capture remains effective. A rise in threshold may shorten battery longevity or require output changes, while loss of capture can produce a wider paced QRS and alter the intended physiological effect.
After AV node ablation, programming must be approached carefully because the patient may be pacing-dependent. Early post-procedure review, wound assessment and confirmation of stable capture are essential. Longer-term surveillance should address AF symptoms, anticoagulation, falls, renal function, blood pressure, congestion and the broader HFpEF treatment plan. Device success should never be judged in isolation from the patient’s overall functional trajectory.
Integrating HBP with comprehensive AF care
HBP is one component of a treatment strategy rather than a replacement for established AF and HFpEF care. Stroke prevention remains fundamental, with anticoagulation decisions based on validated risk assessment and clinical context. Australian prescribers must also consider medication access, monitoring requirements and the patient’s ability to attend follow-up, particularly outside major cities.
Lifestyle and comorbidity management can influence both AF burden and HFpEF symptoms. Blood pressure control, weight management, treatment of obstructive sleep apnoea, diabetes care and moderation of alcohol intake may all be relevant. For some patients, reducing excess alcohol is particularly important given the established association between heavy intake and recurrent AF; advice should be practical and culturally appropriate rather than punitive.
The Australian health system offers meaningful advantages in specialist care, yet geography can complicate continuity. Patients in Sydney, Melbourne, Brisbane, Adelaide or Perth may have relatively direct access to electrophysiology teams, while those in rural and remote communities may depend on visiting services, shared-care arrangements and telehealth. Remote device monitoring can reduce travel, although it does not remove the need for local clinical assessment when symptoms, wound problems or lead issues occur.
Clinicians who want to compare procedural approaches, review pacing outcomes or follow emerging guidance can use the Journal of Arrhythmia as a source of peer-reviewed material in electrophysiology and cardiac rhythm management. Its scope is relevant to trainees and specialists evaluating how conduction system pacing fits into contemporary AF and heart failure practice.
As the field develops, research should focus on patient-centred outcomes in well-defined HFpEF populations. Useful endpoints include exercise capacity, congestion, hospitalisation, quality of life, AF symptom burden, lead performance and the need for system revision. Prospective comparisons between HBP, left bundle branch area pacing, biventricular pacing and conventional right ventricular pacing would help clarify which patients gain the greatest benefit.
His bundle pacing may be a thoughtful option for selected patients with AF and HFpEF, particularly when AV node ablation or a high ventricular pacing burden is expected. Its physiological appeal is persuasive, but implementation requires technical skill, reliable follow-up and an honest discussion that the evidence base is still evolving.
Clinicians and trainees can explore current studies, reviews and guidance in the journal’s article collection to support evidence-informed decisions about conduction system pacing, AF management and heart failure care.