His Bundle Pacing and Biventricular Pacing in Heart Failure
Cardiac resynchronization therapy has changed the treatment of selected patients with heart failure, reduced left ventricular ejection fraction, and electrical dyssynchrony. Biventricular pacing (BiV-CRT) remains the best-established approach, particularly for patients with sinus rhythm, left bundle branch block (LBBB), and a broad QRS complex. His bundle pacing (HBP) offers a different strategy: it attempts to restore activation through the heart’s native His–Purkinje system rather than stimulating the ventricles from a coronary venous lead.
The comparison is clinically important because electrical resynchronization is not uniform. Some patients respond dramatically to BiV-CRT, while others have suboptimal coronary sinus anatomy, phrenic nerve stimulation, lead instability, or persistent mechanical dyssynchrony. HBP may provide a more physiological activation pattern in carefully selected patients, but implantation can be technically demanding and long-term evidence remains less mature.
A meaningful assessment therefore requires more than comparing ejection fraction before and after implantation. QRS correction, pacing thresholds, lead durability, heart failure hospitalization, functional capacity, arrhythmia burden, and survival all contribute to the therapeutic decision. The balance between established evidence and individual anatomy should guide device selection.
Electrical Resynchronization In Heart Failure
Ventricular conduction delay causes different myocardial regions to contract at different times. In patients with LBBB, septal contraction may occur prematurely while the lateral wall contracts late, reducing stroke volume and increasing wall stress. Chronic dyssynchrony can worsen mitral regurgitation, promote adverse remodeling, and amplify symptoms of congestion.
BiV-CRT addresses this problem by pacing the right ventricle and the left ventricle, usually through a right ventricular lead and a coronary sinus lead positioned over a lateral or posterolateral branch. The goal is to narrow the QRS and coordinate ventricular contraction. Its strongest clinical benefit is seen in patients with LBBB morphology, a QRS duration of at least 150 milliseconds, and left ventricular systolic dysfunction despite guideline-directed medical therapy.
HBP delivers stimulation at or near the His bundle, distal to the atrioventricular node. When the diseased conduction system can be recruited, the impulse travels through the native bundle branches and Purkinje network. This can produce selective His capture, with a narrow QRS, or nonselective capture, in which nearby myocardium is activated alongside the His bundle.
How The Two Strategies Work
The principal strength of BiV-CRT is its extensive clinical foundation. Randomized trials have demonstrated improvements in symptoms, ventricular remodeling, quality of life, and selected survival outcomes. The approach can also provide reliable rate support and defibrillator therapy when a CRT-D system is indicated. However, response depends on lead location, scar distribution, venous anatomy, atrioventricular timing, and the percentage of effective biventricular pacing.
HBP is attractive because it uses the patient’s intrinsic conduction architecture. A successful implant may correct or narrow a bundle branch block, reduce interventricular and intraventricular delay, and avoid direct stimulation of the ventricular myocardium. This is especially relevant in patients who develop pacing-induced cardiomyopathy or who require a high burden of ventricular pacing with an anticipated risk of dyssynchrony.
The physiological concept does not guarantee procedural simplicity. The His bundle is a small target near the tricuspid annulus and membranous septum. Thresholds may be higher than those of conventional right ventricular pacing, sensing can be challenging, and lead revision or an additional backup lead may be needed. If infra-Hisian disease is advanced, HBP may fail to correct the conduction defect even when the lead is positioned accurately.
Comparative Evidence And Clinical Outcomes
Comparative studies generally suggest that HBP can achieve narrower paced QRS complexes and favorable echocardiographic remodeling in selected patients. Some observational cohorts report improvements in left ventricular ejection fraction, New York Heart Association functional class, and heart failure hospitalization comparable to or better than conventional BiV-CRT. These findings are encouraging but should be interpreted carefully because HBP studies often include smaller, highly selected populations and vary in definitions of procedural success.
BiV-CRT has more consistent evidence across broad heart failure populations. Its limitations are also well characterized: approximately one-third of recipients may show limited clinical or structural response, although the definition of “nonresponse” differs between studies. HBP may be particularly useful after failed coronary sinus lead placement or in patients with a narrow venous target, while BiV-CRT remains the default when guideline-supported indications are clear and implantation is feasible.
| Clinical consideration | His bundle pacing | Biventricular pacing |
|---|---|---|
| Activation strategy | Recruits the native His–Purkinje system | Stimulates right and left ventricular sites |
| QRS effect | May restore or substantially narrow QRS when conduction disease is correctable | Often narrows QRS in LBBB, though response varies |
| Evidence base | Growing observational and prospective comparative evidence | Large randomized trial and registry experience |
| Implantation | Precise septal targeting; mapping and threshold assessment are important | Coronary sinus anatomy may complicate lead placement |
| Pacing threshold | Can be higher and may rise over time | Usually more predictable for ventricular capture |
| Best-supported role | Selected patients, pacing-induced cardiomyopathy, or failed BiV lead placement | Standard CRT indication with suitable venous anatomy |
| Key limitations | His capture failure, lead revision, battery drain, backup pacing concerns | Nonresponse, phrenic stimulation, lead dislodgment, venous constraints |
Outcomes also depend on the underlying substrate. Patients with extensive myocardial scar, severe right ventricular dysfunction, advanced renal disease, or persistent atrial fibrillation may respond differently from patients with isolated LBBB and relatively preserved right ventricular function. A direct comparison should therefore incorporate baseline phenotype rather than treating all CRT candidates as one group.
Selecting Patients And Planning Implantation
HBP can be considered for patients with heart failure and reduced ejection fraction who meet a resynchronization indication, particularly when conventional BiV-CRT is unsuccessful or unlikely to provide effective capture. It may also be reasonable for patients expected to require frequent ventricular pacing, including those with atrioventricular block and a reduced ejection fraction. In pacing-induced cardiomyopathy, correcting the source of dyssynchrony is often a central therapeutic objective.
A detailed electrocardiographic assessment is essential. QRS morphology, duration, atrioventricular conduction, rhythm status, and the presence of intermittent bundle branch block help predict whether His capture can correct the electrical abnormality. Operators should document pacing thresholds, selective versus nonselective capture, sensing values, and the response to changes in output. A backup ventricular lead may be appropriate when there is a high risk of loss of capture or progressive conduction disease.
Device choice should also reflect local expertise and follow-up capacity. HBP requires experience with electrophysiological mapping, fluoroscopic or electroanatomic localization, and careful interpretation of paced electrograms. The expanding special issue collection literature on pacing, ablation, and device therapy can help clinicians follow evolving approaches to conduction system pacing and resynchronization.
Procedural Risks And Long-Term Management
The main procedural concern with HBP is failure to achieve stable, reliable His capture. Lead dislodgment, rising thresholds, loss of selective capture, and battery depletion can compromise the intended physiological benefit. A patient who depends on pacing requires a clear contingency plan, including remote monitoring and prompt evaluation of threshold changes.
BiV-CRT carries different technical risks. Coronary sinus lead implantation may be limited by venous occlusion, tortuous branches, unstable lead position, or unacceptable phrenic nerve stimulation. The procedure may also require contrast exposure and longer fluoroscopy time. When a suitable lateral or posterolateral branch cannot be reached, alternative strategies include surgical epicardial placement, multipoint pacing in selected systems, or conduction system pacing.
Atrial arrhythmias add another layer of complexity. Persistent atrial fibrillation can reduce effective BiV pacing because of rapid intrinsic conduction, and atrioventricular node ablation may be considered when rate control prevents near-continuous pacing. The clinical context of arrhythmia intervention can be informed by reports on ablation outcomes, particularly when frailty, age, anticoagulation, and complication risk influence procedural planning.
Imaging, Substrate And Response Assessment
Echocardiography remains central to follow-up. Left ventricular ejection fraction, end-systolic volume, mitral regurgitation, right ventricular function, and filling pressures can show whether resynchronization is producing reverse remodeling. Speckle-tracking echocardiography may add information about mechanical dispersion and regional contraction, although its role in routine device selection varies.
Cardiac magnetic resonance imaging can identify ischemic or nonischemic scar and estimate the likelihood that a paced wavefront will recruit viable myocardium. Scar in the posterolateral left ventricular wall may reduce the benefit of a conventional coronary sinus lead placed in that region, while septal or diffuse fibrosis may limit the ability of HBP to correct conduction disease. Research involving atrial fibrosis imaging also illustrates how tissue characterization can refine arrhythmia and device-risk assessment.
Follow-up should combine symptoms with objective device data. Clinicians should review pacing percentages, stored arrhythmia episodes, lead impedance, capture thresholds, battery longevity, and QRS morphology. A narrow paced QRS is useful, but it should not replace assessment of congestion, exercise tolerance, renal function, medication adherence, and recurrent hospitalization.
Practical Recommendations For Device Selection
- Use guideline-directed medical therapy and a complete electrocardiographic assessment before selecting a resynchronization strategy.
- Favor BiV-CRT when the patient has a strong conventional indication, suitable coronary sinus anatomy, and access to an experienced CRT implantation team.
- Consider HBP when physiological conduction capture is achievable, especially after failed BiV lead placement or in pacing-induced cardiomyopathy.
- Confirm capture type, threshold stability, sensing, and QRS response during implantation and at structured follow-up visits.
- Incorporate scar imaging, rhythm status, ventricular function, frailty, and anticipated pacing dependence into shared clinical decision-making.
The available evidence supports a complementary rather than competitive relationship between the two approaches. BiV-CRT remains the benchmark against which newer pacing strategies should be evaluated, while HBP expands the options for patients with difficult anatomy, failed conventional therapy, or a strong rationale for physiological activation. Left bundle branch area pacing may also enter this discussion, but it should not obscure the specific advantages and limitations of direct His bundle recruitment.
Future comparative trials need standardized definitions of procedural success, durable conduction capture, clinical response, and device-related complications. Longer follow-up is particularly important because a favorable early ejection fraction response may not predict lead stability or battery performance over several years. Until those data mature, individualized selection and expert implantation remain decisive.
Clinicians, researchers, and trainees can use the Journal of Arrhythmia’s peer-reviewed resources to follow emerging evidence in conduction system pacing, CRT optimization, heart failure electrophysiology, and implantable devices. Applying that evidence to carefully characterized patients will help ensure that the chosen pacing strategy delivers durable electrical and clinical benefit.